HanweiSmart Gas

Search Hanwei Smart Gas

Products, solutions and technical guides

Hanwei Smart Gas

Home / Vehicle-mounted Methane Leak Detection System

Vehicle-mounted Methane Leak Detection System

Combine VMLD700II Pro roof-mounted remote laser screening with a front-mounted V8 or V9 CH4/C2H6 extractive unit, positioning, wind data and patrol software.

Vehicle-mounted Methane Leak Detection System business scene visual

Pipeline Safety

Product selection can be reviewed by installation environment, gas type and target-market requirements.

Answer Summary

Hanwei Smart Gas provides a Vehicle-mounted Methane Leak Detection System, combining complementary detection modules rather than a single detector. The roof-mounted VMLD700II Pro unit performs remote, non-contact methane screening. A front-mounted V8 or V9 extractive unit measures CH4 and C2H6 in sampled air. Choose V8 or V9 according to the required detection range and sensitivity. Positioning, wind data, an onboard controller and GIS / patrol software support source-area assessment, evidence recording and field follow-up.

One system · complementary detection modules

Vehicle-mounted Methane Leak Detection System

Roof-mounted · Remote laser detection

VMLD700II Pro

Remote, non-contact methane screening

Front-mounted · Extractive CH4 / C2H6 detection

V8

Wide-range CH4 / C2H6 detection configuration

OR

V9

Ultra-high-sensitivity CH4 / C2H6 detection configuration

+

Positioning · Wind Data · Onboard Controller · GIS / Patrol Software

Choose V8 or V9 according to the required detection range and sensitivity. They are selectable front-mounted modules within the system.

Roof-mounted Remote Laser Unit

VMLD700II Pro — Roof-mounted Remote Laser Methane Detection Unit

Installation
Roof-mounted
Measurement role
Remote laser methane screening of suspicious areas
Performance
Request the selected remote unit’s datasheet and survey conditions. Extractive-unit ppb sensitivity and concentration ranges do not specify remote screening distance.

Front-mounted Extractive Unit Comparison

V8 and V9 measure sampled CH4 / C2H6. These specifications belong to the front-mounted extractive units, not the roof-mounted remote unit.

Front-mounted V8 and V9 configuration comparison
ParameterV8 · Wide rangeV9 · Ultra-high sensitivity
CH4 sensitivity<10 ppb1 ppb
C2H6 sensitivity<70 ppb0.5 ppb
CH4 range0–100%LEL0–10000 ppm
C2H6 rangeConfirm the range and unit in the supplied datasheet0–1000 ppm
Sampling flowConfirm module-specific sampling flowConfirm module-specific sampling flow
ResponseConfirm response and sampling conditionsConfirm response and sampling conditions

Confirm the complete model-specific datasheet, measurement conditions and sampling arrangement before procurement. Remote screening distance is not an extractive-unit parameter.

Screen first. Verify second.

  1. 1.Screen

    Use remote laser screening to identify suspicious methane areas.

  2. 2.Sample

    Collect air through the front-mounted extractive sampling arrangement.

  3. 3.Distinguish

    Review CH4 and C2H6 measurements to support gas-source assessment.

  4. 4.Locate

    Combine positioning and wind data to assess the suspected source area.

  5. 5.Record

    Associate indications with route and survey evidence in GIS / patrol software.

  6. 6.Act

    Assign field investigation and record the findings and follow-up actions.

Technical Details & Selection Notes

Specifications to be confirmed by product model and target market.

System integrationPositioning, wind data, onboard controller and GIS / patrol software; agree included hardware and software interfaces.
Configuration selectionOne roof-mounted remote laser module plus a selected front-mounted V8 or V9 extractive module. Confirm the final supply list.
CertificationCertification availability depends on the selected configuration and target market. Contact Hanwei Smart Gas for project-specific compliance information.

Choose a Laser Methane Inspection Setup for Your Patrol Route

Vehicle-mounted laser inspection supports mobile screening for suspected methane leaks along city gas patrol routes. The useful configuration depends on road access, the vehicle, the required gas indications and how the team verifies findings in the field.

  1. 01

    Describe the route

    Identify patrol areas, access restrictions, proposed vehicle and current inspection method.

  2. 02

    Review detection scope

    Confirm methane or methane/ethane indication, mounting and operating conditions by model.

  3. 03

    Record indications

    Agree route, location and event records needed for the inspection workflow.

  4. 04

    Verify in the field

    Use the agreed field-check procedure before repair decisions and follow-up records.

A screening indication is not a confirmed leak location or an emissions-rate measurement. Detection distance, sensitivity, patrol speed and gas channels require model-specific evidence.

Road-accessible network patrol

Inspection teams can cover the target area using a vehicle.

Configuration to review

Review roof-mounted VMLD700II Pro remote screening plus a front-mounted V8 or V9 extractive module. Confirm positioning, wind data, onboard control and GIS / patrol software.

Practical value

Connects equipment selection to the patrol and field-verification process.

Check before selection

Vehicle integration, gas channels, mounting, power, operating conditions, route records and reporting format.

Narrow streets and communities

A full-sized inspection vehicle is inconvenient for the intended route.

Configuration to review

Review the electric-bike laser inspection option and local access conditions.

Practical value

Offers a different patrol arrangement for route assessment.

Check before selection

Access permissions, operator arrangements, telemetry or sampling configuration, battery and data transfer.

Follow-up on a suspected indication

The team needs a field check after patrol screening.

Configuration to review

Discuss appropriate portable equipment; consider EGC200 when ethane identification is part of the task.

Practical value

Separates initial screening from the evidence needed for a field decision.

Check before selection

Target gas, sampling approach, identification requirements, records and operator procedure.

Prepare Your Technical Inquiry

Send the country, patrol route description, proposed vehicle, existing method and required records. Request the model-specific datasheet and an agreed demonstration scope covering installation, operating conditions, field verification, training and service. Agree acceptance criteria before planning a wider rollout.

No registration required. Fill in what you know, then paste the relevant details into your inquiry.

Product Overview

Screen first. Verify second. Remote laser screening identifies suspicious methane areas; front-mounted extractive detection provides high-sensitivity CH4/C2H6 measurement. Positioning and wind data help interpret an indication, while the onboard controller and GIS / patrol software associate it with the route and survey record. Field teams investigate suspected sources and record actions. A screening indication is not proof of an exact leak source or an emissions rate.

Product category

Pipeline Safety

Road-accessible city gas transmission and distribution pipeline surveys, utility patrol and suspected-leak follow-up.

Roof-mounted remote methane screening with VMLD700II Pro

Front-mounted extractive CH4/C2H6 detection: select V8 or V9

Positioning and wind data for source-area assessment

Onboard controller and GIS / patrol records for investigation and action

Application Fit & Installation Boundary

Select products for the installation environment, gas type and system role.

Application fit

Select the system for road-accessible pipeline surveys requiring remote screening and sampled CH4/C2H6 measurement. V8 is the wide-range configuration; V9 is the ultra-high-sensitivity configuration. Neither designation establishes a replacement or generation relationship.

Installation context

Mount the remote laser unit on the roof and the extractive sampling unit at the front of the vehicle. Confirm vehicle mounting, sample path, power, positioning, wind instruments, controller and GIS / patrol software in the supplied configuration.

Selection boundary

V8 and V9 are selectable front-mounted modules, not two complete patrol systems. Remote distance is not an extractive-unit specification. Confirm performance under survey conditions; methane/ethane measurements and location records support assessment but do not prove a leak source, emissions rate or compliance.

Typical Applications

Common gas safety scenarios where this product category can support monitoring, alarm verification or response workflows.

Road-accessible city gas distribution pipeline surveys

Utility patrol and suspected methane source-area assessment

Recorded follow-up from screening indication to field investigation

How It Fits Into a Project

A product category can be selected as part of a field-to-platform safety workflow instead of as an isolated device purchase.

1Screen
2Sample
3Distinguish
4Locate
5Record
6Act

Why Hanwei

Hanwei Smart Gas can support product selection within wider gas safety monitoring and local partner cooperation discussions.

Combines remote screening and sampled CH4/C2H6 measurements within a utility patrol system
Keeps detector selection, vehicle integration and software scope explicit
Links patrol indications to field investigation and documented actions

Related Products

Adjacent product categories for combined gas safety projects.

Solution Mapping

Associated solution paths for buyer evaluation and pilot planning.

Related Knowledge

Read related technical guides and application insights.

Certification availability varies by product and target market. Contact us for confirmed specifications.

FAQ

Common questions for early product selection and project discussion.

Is this a single detector or a complete system?

It is a vehicle-mounted system built from complementary modules: roof-mounted remote laser screening, a selected V8 or V9 front-mounted extractive unit, and positioning, wind data, onboard control and GIS / patrol software.

What does the roof-mounted VMLD700II Pro unit do?

It provides remote, non-contact methane screening to identify suspicious areas for assessment. Its remote measurement role is separate from front-mounted air sampling; do not transfer one module’s specifications to another.

How should I choose between V8 and V9?

V8 and V9 are selectable front-mounted extractive detection configurations with different sensitivity and measurement ranges. Choose V8 for the wide-range configuration or V9 for the ultra-high-sensitivity configuration according to your project requirements. Confirm the exact ranges and sampling performance in the offered datasheet.

Does remote screening identify the exact leak source?

A remote methane indication identifies an area for further assessment. Sampled CH4/C2H6 measurements, positioning and wind data support investigation. Field verification is still needed before assigning a leak source and deciding action.

What should be included in a project inquiry?

State the vehicle and route, roof mounting and front sampling arrangements, required range and sensitivity, selected V8 or V9 option, data interfaces, GIS records and field follow-up process. Request module-specific specifications and target-market compliance information.

Product Inquiry

Discuss product selection, pilot scope and target-market requirements with Hanwei Smart Gas.

Discuss Product Selection

Share the application scenario, target gas, installation environment and expected integration method so the appropriate product direction can be reviewed.