Technical details for selection
An Online THT Odorant Monitoring System measures odorant concentration; an odorizer adds odorant to the gas. This page covers sampling-based analysis, not odorant injection equipment. The monitoring system combines a selected analyzer with sampling and project-specific data collection. THT-GC110 is the gas chromatography analyzer; THT-EC110 is an electrochemical monitor for fixed sampling points on pressurized gas pipelines, including medium-pressure network-end locations. THT concentration measurement does not establish suitability for TBM blends or replace a combustible gas leak alarm.
Confirm before ordering
Request the model-specific datasheet, measurement range and accuracy, sample requirements, calibration and consumables information, and applicable certification documents.
Request technical documentation →- GC vs EC — selection roles
- THT-GC110 (gas chromatography) and THT-EC110 (electrochemical) are complementary configurations, not interchangeable datasheets. Official LEC110 copy positions the electrochemical option for network-end THT checks with relatively controllable cost versus chromatograph equipment; confirm the fit for each sampling point.
- THT-GC110 — principle
- Gas Chromatography
- THT-GC110 — published range
- The official LGC110 / THT-GC110 product table lists 100 mg/m³ as a range figure without a clearly labelled lower bound on this portal. Confirm the complete measurement range and units in the supplied datasheet.
- THT-GC110 — carrier gas
- The LGC110 source table lists clean air as carrier gas. Confirm supply quality and conditioning for the THT-GC110 configuration.
- THT-GC110 — power / sample pressure
- Not published as confirmed site figures on this portal — confirm supply voltage, sample pressure limits and conditioning in the THT-GC110 datasheet.
- THT-EC110 — principle
- Electrochemical
- THT-EC110 — measurement range
- 0–50 mg/m³ for the LEC110 / THT-EC110 configuration only. Confirm the supplied model and measurement conditions.
- THT-EC110 — accuracy
- ±5% F.S. is listed for LEC110 / THT-EC110 only; confirm test conditions in the supplied datasheet.
- THT-EC110 — power supply
- 100–240 V AC, 50/60 Hz for the electrochemical analyzer. Confirm the total load for the proposed cabinet and sampling equipment.
- THT-EC110 — sample pressure
- The LEC110 / THT-EC110 source lists pipeline pressure below 500 kPa. Confirm the pressure reference and sample conditioning.
- THT-EC110 — installation
- THT-EC110 / LEC110 is described as fixed-point installation for online THT monitoring on pressurized natural-gas pipelines, including medium-pressure network-end locations. Confirm sampling point design for the proposed station.
- Interfaces and sampling
- Request the selected model’s sampling diagram, calibration requirements and interface list; do not transfer options between models.
- Certification
- Request certificates for the exact supplied model and destination market; product-page markings alone are not certificate verification.