HanweiSmart Gas

Search Hanwei Smart Gas

Products, solutions and technical guides

Natural gas odorization monitoring

Online THT Odorant Analyzer

Measure tetrahydrothiophene in a natural gas sample to support odorant-level records, trend review and exception follow-up.

THT-GC110 · Gas Chromatography

THT-EC110 · Electrochemical

Target
THT odorant
Installation
Sampling-based
Application
Gate stations
Online THT Odorant Analyzer — product image
THT-EC110 cabinet shown for reference (internal / China model: LEC110).
THT-GC110 is a separate gas chromatography configuration (internal / China model: LGC110).

Answer Summary

Hanwei Smart Gas offers the Online THT Odorant Analyzer in two global model configurations: THT-GC110 (gas chromatography; internal / China LGC110) and THT-EC110 (electrochemical; internal / China LEC110). Specifications are model-specific and must not be treated as interchangeable—GC and EC are complementary selection paths. Citeable differences on this page include principle, published range notes, EC accuracy/power/sample-pressure/installation facts, and GC carrier-gas notes; confirm any missing GC power or pressure figures in the supplied datasheet.

Model Reference

Global commercial model names are mapped to the internal / China models used in source documents. Each configuration retains its own specifications.

Global ModelTechnologyInternal / China Model Reference
THT-GC110Gas ChromatographyLGC110
THT-EC110ElectrochemicalLEC110

THT-GC110

Gas Chromatography Configuration

Internal / China Model Reference: LGC110

Discuss THT-GC110 →

THT-EC110

Electrochemical Configuration

Internal / China Model Reference: LEC110

Discuss THT-EC110 →

Check the fit

Technical details for selection

An Online THT Odorant Monitoring System measures odorant concentration; an odorizer adds odorant to the gas. This page covers sampling-based analysis, not odorant injection equipment. The monitoring system combines a selected analyzer with sampling and project-specific data collection. THT-GC110 is the gas chromatography analyzer; THT-EC110 is an electrochemical monitor for fixed sampling points on pressurized gas pipelines, including medium-pressure network-end locations. THT concentration measurement does not establish suitability for TBM blends or replace a combustible gas leak alarm.

Confirm before ordering

Request the model-specific datasheet, measurement range and accuracy, sample requirements, calibration and consumables information, and applicable certification documents.

Request technical documentation →
GC vs EC — selection roles
THT-GC110 (gas chromatography) and THT-EC110 (electrochemical) are complementary configurations, not interchangeable datasheets. Official LEC110 copy positions the electrochemical option for network-end THT checks with relatively controllable cost versus chromatograph equipment; confirm the fit for each sampling point.
THT-GC110 — principle
Gas Chromatography
THT-GC110 — published range
The official LGC110 / THT-GC110 product table lists 100 mg/m³ as a range figure without a clearly labelled lower bound on this portal. Confirm the complete measurement range and units in the supplied datasheet.
THT-GC110 — carrier gas
The LGC110 source table lists clean air as carrier gas. Confirm supply quality and conditioning for the THT-GC110 configuration.
THT-GC110 — power / sample pressure
Not published as confirmed site figures on this portal — confirm supply voltage, sample pressure limits and conditioning in the THT-GC110 datasheet.
THT-EC110 — principle
Electrochemical
THT-EC110 — measurement range
0–50 mg/m³ for the LEC110 / THT-EC110 configuration only. Confirm the supplied model and measurement conditions.
THT-EC110 — accuracy
±5% F.S. is listed for LEC110 / THT-EC110 only; confirm test conditions in the supplied datasheet.
THT-EC110 — power supply
100–240 V AC, 50/60 Hz for the electrochemical analyzer. Confirm the total load for the proposed cabinet and sampling equipment.
THT-EC110 — sample pressure
The LEC110 / THT-EC110 source lists pipeline pressure below 500 kPa. Confirm the pressure reference and sample conditioning.
THT-EC110 — installation
THT-EC110 / LEC110 is described as fixed-point installation for online THT monitoring on pressurized natural-gas pipelines, including medium-pressure network-end locations. Confirm sampling point design for the proposed station.
Interfaces and sampling
Request the selected model’s sampling diagram, calibration requirements and interface list; do not transfer options between models.
Certification
Request certificates for the exact supplied model and destination market; product-page markings alone are not certificate verification.

Plan the sampling point and data connection

This is a sampling-based analyzer. Review sample extraction and pretreatment with the instrument; it is not installed as an inline section of the gas main.

  1. 01

    Pipeline sampling point

  2. 02

    Model-specific sample conditioning

  3. 03

    THT-GC110 or THT-EC110 analyzer

  4. 04

    Confirmed data interface

  5. 05

    Operator review and follow-up

Conceptual selection sequence; the sampling arrangement and communication scope require project confirmation.

Explore the odorization monitoring solution →

Application fit and selection boundary

The product fits natural gas odorization monitoring projects where utilities need THT-related records, trend review and exception follow-up.

The analyzer measures THT odorant in a sampling-based workflow; it does not replace household alarms or ordinary leak detectors, and its readings alone do not establish legal compliance. Confirm the model, sampling method, certification status and target-market requirements.

Select an Online THT Analyzer for Your Sampling Point

Choose THT-GC110 (gas chromatography) or THT-EC110 (electrochemical) for tetrahydrothiophene measurement in a gas sample. Internal / China model references are LGC110 and LEC110, respectively. Start with the odorant and sampling conditions, then define how operators will use the readings. Ambient methane detection is a separate task.

  1. 01

    Define the sample

    Identify the odorant, sampling location, gas conditions and expected concentration units.

  2. 02

    Review the analyzer

    Confirm measurement range, sampling treatment, calibration and service requirements for the model.

  3. 03

    Connect the readings

    Agree local review or data transfer, point identity, timestamps and instrument status.

  4. 04

    Investigate exceptions

    Review sampling and equipment condition with the reading before recording follow-up.

Sampling-based measurement, not an inline section of the gas main. A THT result does not establish suitability for other odorants or regulatory compliance.

A station sampling point

Operators need THT observations at a gate station or odorization point.

Configuration to review

Review the analyzer together with sample extraction and pretreatment requirements.

Practical value

Makes the measurement and its sampling conditions part of the same selection.

Check before selection

THT or blend, expected range and units, sample pressure, calibration materials, utilities and maintenance access.

Several sites in one review workflow

The utility needs to compare records and follow up on exceptions across stations.

Configuration to review

Scope analyzer interfaces and the receiving system separately from the measurement hardware.

Practical value

Keeps point identity, reporting gaps and operator follow-up visible across sites.

Check before selection

Number of points, model-specific interface configuration, units, reporting interval, existing platform and record ownership.

Prepare Your Technical Inquiry

For a technical review, send the country, odorant, sampling-point description, expected range and required interfaces. Request the model-specific datasheet, sampling requirements, calibration and consumables information, and certification documents relevant to your market. State unknown items so the review can identify them.

Download English product selection briefs (PDF, 6 pages)

No registration required. Fill in what you know, then paste the relevant details into your inquiry.

Questions before selecting an analyzer

Are THT-GC110 and THT-EC110 the same analyzer?

No. THT-GC110 uses gas chromatography; THT-EC110 uses electrochemical measurement. Specify the offered model and use only its own datasheet. For documentation traceability, the internal / China model references are LGC110 and LEC110, respectively. These are global commercial model names, not a claim that the domestic models have been renamed.

Is an Online THT Odorant Analyzer the same as a gas leak detector?

No. It is used for THT odorant monitoring in natural gas odorization workflows. It should not be positioned as a household gas alarm or ordinary combustible gas leak detector.

Can it be installed directly on a gas main pipeline?

Source materials describe a sampling-based approach. Sampling point design, pretreatment and station installation conditions should be confirmed during technical discussion.

Can Hanwei provide confirmed accuracy and certification details?

Accuracy, range, certification and target-market approval should be confirmed by product model and project requirements before quotation or public project use.

Can the analyzer measure a THT and TBM blend?

THT monitoring does not establish suitability for TBM or a blended odorant. Provide the odorant composition and ask for model-specific compound selectivity, interference data and calibration requirements before selecting an analyzer.

What should I include in a THT analyzer RFQ?

Include the odorant composition, concentration range and units, sample pressure and temperature, number of points, required analysis interval, installation environment and data interface. Request a model-specific datasheet, sampling diagram, calibration procedure, maintenance requirements and applicable certificates. Download the inquiry checklist in the configuration section to prepare your request.

Is this product an odorizer or odorant injection system?

No. An Online THT Odorant Analyzer measures tetrahydrothiophene concentration in a sampling-based arrangement. An odorizer adds odorant. This product page and the odorization monitoring solution cover monitoring and operator records, not injection equipment or automatic dosing control.

Are certifications available?

Certification availability varies by product and target market. Contact us for confirmed specifications.

Certification availability varies by product and target market. Contact us for confirmed specifications.

Review your THT monitoring requirement

Share your country, odorant, sampling-point conditions, expected measurement range and required interfaces. You can mark any unknown items for review.

Request a THT Analyzer Review

The inquiry form carries this product selection with you.

Contact / Inquiry Form

Share your product interest, target market and application scenario so our team can review your inquiry and contact you.

You can also contact [email protected]. For technical drawings or equipment photos, ask our team about a suitable transfer method. Share only material you are authorized to disclose and include your inquiry reference when available.