Hanwei Smart Gas
Home / GTY-CXL Standalone Combustible Gas Detector
GTY-CXL Standalone Combustible Gas Detector
Standalone combustible gas detector for commercial kitchens, gas stations, regulating stations and small boiler room safety projects.

Gas Detection
Product selection can be reviewed by installation environment, gas type and target-market requirements.
Product Overview
GTY-CXL is a standalone combustible gas detector for natural gas or LPG leak awareness in commercial and light industrial sites. It provides local alarm operation, with data reporting options subject to model and project confirmation. Installation is near potential leak sources, using a mounting arrangement confirmed for the selected model and site. Final target gas, sensing principle, communication option and certification status should be confirmed by model and target market.
Product category
Gas Detection
Commercial kitchens, restaurants, gas stations, regulating stations, boiler rooms and gas-using facilities.
Local alarm workflow for site safety response
Fixed installation near potential leak sources, with mounting arrangement confirmed by model and site
Optional data reporting by model and project confirmation
Commercial kitchen and station-area monitoring, subject to site and model selection
Application Fit & Installation Boundary
Select products for the installation environment, gas type and system role.
Application fit
GTY-CXL fits commercial and light industrial combustible gas leak monitoring around potential gas-use or equipment risk areas.
Installation context
Mount the detector near the potential leak source after site assessment. Confirm wall or other fixed mounting arrangements for the selected model before installation.
Selection boundary
GTY-CXL detects leaked gas in the surrounding environment; it is not an inline gas main instrument. Confirm the target gas, alarm configuration and installation conditions before selection.
Typical Applications
Common gas safety scenarios where this product category can support monitoring, alarm verification or response workflows.
Commercial kitchen gas leak monitoring
Gas station or fuel station combustible gas safety
Regulating station and gate station safety monitoring
Small boiler room and commercial gas equipment areas
Product Selection Notes
Specifications to be confirmed by product model and target market.
| Target gas | Natural gas or LPG combustible gas scenarios by model confirmation. |
|---|---|
| Detection mode | Catalytic combustion or infrared absorption by sensor configuration; natural diffusion and continuous environmental monitoring, not inline measurement. |
| Power supply / consumption | AC220V +/-44V; 24V supply option; <=3W. Select the supply configuration before installation. |
| Response time | T90 <=30 seconds for the specified configuration. |
| Alarm output | Local audible and visual alarm operation without a separate controller; 2 normally open contact groups rated 3A at DC30V. Check response-device loads and the required alarm linkage. |
| Wireless communication | LoRa at 433MHz for the specified wireless configuration. Confirm receiver compatibility and target-country radio requirements; this is not a universal cellular connection. |
| Additional configuration requests | 4-20mA, cellular reporting (4G / NB-IoT / 5G) or battery backup require separate hardware and availability confirmation. They are not included in the LoRa configuration described here. |
| Operating conditions | -40 to +70°C for the catalytic configuration; <=95% RH, non-condensing; IP66. Confirm the infrared configuration temperature range and site weather protection. |
| Dimensions / weight | 130 x 157 x 78 mm; less than 1.1 kg. |
| Housing / cable entry | Aluminum alloy; 4 NPT1/2 entries. Confirm cable glands and sealing for the installation. |
| Local operation | Infrared remote control for configuration and calibration procedures. |
| Installation | Wall or external pipe mounting near potential leak sources; confirm the mounting accessories and position. The detector is not inserted into the gas pipe. |
| Certification | Certification availability varies by product and target market. Contact us for confirmed specifications. |
How It Fits Into a Project
A product category can be selected as part of a field-to-platform safety workflow instead of as an isolated device purchase.
Why Hanwei
Hanwei Smart Gas can support product selection within wider gas safety monitoring and local partner cooperation discussions.
Related Products
Adjacent product categories for combined gas safety projects.
Solution Mapping
Associated solution paths for buyer evaluation and pilot planning.
Related Knowledge
Read related technical guides and application insights.
Certification availability varies by product and target market. Contact us for confirmed specifications.
FAQ
Common questions for early product selection and project discussion.
Are detailed specifications available?
Detailed specifications can be confirmed by product model, installation environment and target market. Hanwei can support product selection during technical discussion.
Are certifications available?
Certification availability varies by product and target market. Contact us for confirmed specifications.
Product Inquiry
Discuss product selection, pilot scope and target-market requirements with Hanwei Smart Gas.
Discuss Product Selection
Share the application scenario, target gas, installation environment and expected integration method so the appropriate product direction can be reviewed.